Engineering library

Connection Library

Repeated welded connections are identified by an engineering fingerprint, calculated once, checked locally and reused across every occurrence. A job card covers one configuration, never an already-aggregated model quantity.

Local demonstration library. Section dimensions are transcribed from EN standards, not a company-approved catalog. Approvals are browser records made inside FABRIX, never authenticated company engineering approvals. Nothing here has been signed by an authorized engineer.
Registered connections
14
0 duplicate identities ignored
Repeated configurations
5
1 configuration(s) appear more than once
Locally checked calculations
1
1 record(s) retained, including superseded
Connection job cards
0
0 current · 0 draft · 0 historical

Repeated connection groups (5)

Grouped by fingerprint, never by profile or mark alone
StatusConfigurationCountTemplateCalculation
Exact
IPE 220 → PL 15
Single-V · θ 60° · root face 2 mm · root gap 2 mm
30DAC2B21744
10CT-EP-IPE220-01 rev 2Checked · reusable
Partial
IPE 220 → PL 15
Single-V · θ 50° · root face 2 mm · root gap 3 mm
1E965C274059
1—Not calculated
Partial
IPE 220 → PL 15
Single-V · θ 60° · root face 2 mm · root gap 2 mm
4FAD16E35C02
1—Not calculated
Data required
IPE 220 → PL 15
Single-V · θ 60° · root face 2 mm · root gap —
97F3D8841B48
1—Not calculated
Partial
IPE 240 → PL 15
Single-V · θ 60° · root face 2 mm · root gap 2 mm
FEB4EF271088
1—Not calculated

Selected configuration

Exact match10 occurrence(s) · A-101, A-102, A-103, A-104, A-105
PrimaryIPE 220 · S355J2
Primary dimensionsh 220 · b 110 · tw 5.9 · tf 9.2 mm
SecondaryPlate 300 × 200 × 15 mm · S355J2
Joint preparationSingle-V · θ 60° · root face 2 mm · root gap 2 mm
Joint thickness9.2 mm
Fillet6 mm leg · both sides
Weld procedureFCAW · shop
NDTUT 10% · from library
TemplateIPE 220 end plate — 6 mm web fillet
Fingerprint30DAC2B21744
The model states no NDT requirement; template CT-EP-IPE220-01 rev 2 requires UT 10% of the groove weld. The template requirement is applied — verify it for this connection.
The source declares template CT-EP-IPE220-01 rev 1, which is superseded by CT-EP-IPE220-01@2. FABRIX matches on the engineering parameters, not on the declared reference.

Latest record CALC-DEMO-IPE220-EP-001 · locally checked by Demo engineering (local record)

Occurrences in this configuration (10)

AssemblyPrimary markSecondary markProfilePreparationProcessModel evidence
A-101BM-01EP-01IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-101BM-02EP-02IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-102BM-03EP-03IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shop220 mm WELD_LENGTH
A-102BM-04EP-04IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-103BM-05EP-05IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-103BM-06EP-06IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-104BM-07EP-07IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-104BM-08EP-08IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-105BM-09EP-09IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model
A-105BM-10EP-10IPE 220Single-V · θ 60° · root face 2 mm · root gap 2 mmFCAW · shopNot reported by the model

The demo register is not a Tekla export. Rows without model evidence are hand-written demonstration data; they are never presented as measured quantities.

Register actions

A repeated import updates the same object; it never adds a second row. The Tekla bridge has been exercised against the companion's reference fixture only, never inside a licensed Tekla installation.

Add a connection by hand

Nothing is guessed: a blank root gap holds the calculation back. A joint thickness left blank falls back to the section flange thickness and says so.